Home Company Info Product List Contact Details
Homeproduct Directory

LX36-8Series limit switch

LX36-8Series limit switch
company ZHEJIANG LIXIN HOIST SWITCH FACTORY
Categories Limit Switches
Update2010-12-30
Original RegionChina
LX36-8Series limit switch
  • Use

The LX36-8 hoist crane (hereafter refers to as limit switch) with the
limit switch, this product mainly uses in exchanging 50HZ, 60HZ, the
fixed working voltage to 380V, the direct current fixed working
voltage to in the 220V control circuit, with by limits the hoist crane
rotary motion organization the work corner and carries on the
sequential control.

  • Classification
    2.1Model meaning
    2.2The limit switch can reliably work under the following condition;
    2.2.1Altitude above sea level
    The installation site altitude above sea level does not surpass
    2,000 meters;
    2.2.2Medium temperature
    The surrounding air medium temperature is not higher than +75
    ℃ and is not lower than -25 ℃;
    2.2.3Relative humidity
    The installation site wettest monthly mean air relative
    humidity is not bigger than 90% (this monthly mean lowest temperature
    not to be bigger than +25 ℃);
    2.2.4Environmental condition pollution rank
    The environmental condition pollution rank is III level;
    2.2.5Installs the category
    Installs the category is III kind;
    2.3Limit switch type
    2.3.1 structure pattern
    According to structure pattern minute: This product structure
    is the rotary system, the speed ratio includes: 80: 1st, 40: 1st, 20:
    1 this 3 kinds.
    2.3.2Control loop
    According to control loop minute: This limit switch are most
    may install 8 control loops.
  • Structure outline

    The limit switch as soon as has by the main axle through the gear reduction system may adjust the cam shaft and the symmetrical compound arrangement which the cam piece group combines the control system three knots which constitute in its two sides microswitch is a body
installs in the protection rank is in the IP64 outer covering, its contour and installs the size to see Figure 1. Attempts the 1LX36-8 limit switch outline drawing one.

  • Parameter

4.1 basic parameter limit switch basic parameter see Table 1
Table 1

Fixed control capacity

Fixed working voltage(Ue)(V)

Fixed working voltage(le)(A)

The agreement gives off heat the electric current(lth)(A)

Fixed operating frequency (/Hour)

Fixed insulation voltageUi(V)

300VAAC

380

0.8

6

300

380

220

1.36

10WDC

220

0.045

110

0.09

4.2Puts through the minute to break
Limit switch putting through breaks the ability with the minute
to see Table 2
Table 2

Use category

Fixed operating current(le)

Puts through the condition

The minute breaks the condition

l(A)

U(A)

COST0.95(ms)

Lc(A)

Ur(V)

COST0.95(ms)

AC-11

380V0.8

8.8

418

0.7

8.8

418

0.7

DC-11

220V、10W 0.045A

0.05

242

300 ms

0.05

242

300 ms

4.3Electricity life
The limit switch electricity life in correspondingly under the
exploitation conditions which arranges in order in table 3, does not
have to repair the type replacement components the load operation to
dodge the number is 100,000.
Table 3

Use category

Puts through the condition

The minute breaks the condition

l(A)

U(A)

COST0.95(ms)

Lc(A)

Ur(V)

LX36-8Series limit switch on sale